Applications
Our Classic-120 multi-parameter monitor is a cost effective and easy to use
patient monitor. It can be used for monitoring of various parameters of SpO2,
NIBP, Pulse, TEMP, ECG, and RESP. Other optional monitoring applications are
also available, such as mainstream, sidestream EtCO2 and 1-Channel
IBP.
Features
1. The Classic-120 multi-parameter monitor uses 12.1 "color TFT display,
which allows simultaneous display of 4 curves.
2. Visual and audible alarms with individual alarm setting are available.
3. Maximum 480 hours trend graphs enable nearly all parameters and trends to be listed.
4. The multi-parameter monitor provides accessories for all adult, pediatric and neonatal patients.
5. It can store up to 400 groups of NIBP data.
6. The patient monitor can be mounted or mounted with rolling stand.
7. It can be networked with the central monitoring system.
2. Visual and audible alarms with individual alarm setting are available.
3. Maximum 480 hours trend graphs enable nearly all parameters and trends to be listed.
4. The multi-parameter monitor provides accessories for all adult, pediatric and neonatal patients.
5. It can store up to 400 groups of NIBP data.
6. The patient monitor can be mounted or mounted with rolling stand.
7. It can be networked with the central monitoring system.
Specifications of Classic-120 Multi-Parameter Monitor
ECG
|
Heart
rate display range
|
15bpm
~ 350bpm
|
|
Heart
rate display accuracy
|
± 1% or ± 2bpm,
whichever is greater
|
||
Sweeping
speed
|
12.5mm/s,
25mm/s, 50mm/s
|
||
Sensitivity
selection
|
×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
|
||
CMRR
|
≥ 89dB
|
||
RESP
|
Measuring
range
|
0rpm~120rpm
|
|
Accuracy
|
±5% or ±2 rpm
|
||
Alarm
limits setting range
|
0rpm~120rpm
|
||
TEMP
|
Measuring
range
|
25.0℃ ~45.0℃
|
|
Measuring
accuracy
|
±0.2℃
|
||
Responding
time
|
≤150s
|
||
NIBP
|
Measuring
method
|
Oscillometric
Technique
|
|
Measuring
range
|
0
mmHg~300mmHg
|
||
Accuracy
|
Maximal
mean difference
|
±5 mmHg
|
|
Maximal
standard deviation
|
8 mmHg
|
||
Measurement
range
|
Adult
|
SYS 40
~ 255 mmHg
|
|
MAP 20
~ 215 mmHg
|
|||
DIA 10
~ 195 mmHg
|
|||
Pediatric
patient
|
SYS 40
~ 200 mmHg
|
||
MAP 20
~ 165 mmHg
|
|||
DIA 10
~ 150 mmHg
|
|||
Neonate
|
SYS 40
~ 135 mmHg
|
||
MAP 20
~ 110 mmHg
|
|||
DIA 10
~ 95 mmHg
|
|||
SpO2
|
Measuring
range
|
35%~100%
|
|
Low
perfusion capability
|
0.4%~5%
|
||
Accuracy
|
Not
greater than 3% for SpO2range from 70% to 100%
|
||
PR
|
Measuring
range
|
30bpm~240bpm
|
|
Measuring
accuracy
|
±2bpm or ±2%,
whichever is greater
|
As
a specialized multi-parameter monitor manufacturer and supplier in China, we also
provide surgical operating table, anesthetic machine, fetal Doppler monitor, and
water purification system, among others.