2013年10月21日星期一


 





















Anesthesia/Anesthetic Machine » Anaeston 3000 Anesthetic Machine

Product Overview
 
Anaeston 3000 anesthetic /anesthesia machine provides an affordable and flexible anesthesia solution for now and the future. Our customers can start with routine application. The anesthetic machine is upgradeable to better meet customers' anesthetic requirements. Modern anesthetic workstation expansion is also feasible to greatly improve the workflow and cut down the operating cost.
Applications
 
Anaeston 3000 anesthetic machines can be used for inhalational anesthesia delivery and management for adult, pediatric and neonatal patients.
Features
 
1. The anesthetic machine offers electronic PEEP function.
2. It has automatic tidal volume compensation, except Anaeston 3000C.
3. It provides a high-precision output as low as 20ml.
4. The anesthetic machine uses autoclavable and latex free components.
5. It can be easily maintained and cleaned without specialized tools.
6 It is CE certified, giving users peace of mind.

Model

Anaeston 3000P

Anaeston 3000PS

Anaeston 3000C

Dimension


810x810x1360 mm (WxDxH)


810x810x1360 mm (WxDxH)

810x634x1360 mm (WxDxH)

Weight

96kg

96kg

70kg



Vaporizer

1 (secondary is optional)

1 (secondary is optional)

1 (secondary is optional)

 Anesthetic type

Halothane, Enflurane, Isoflurane,
Sevoflurane, Desflurane


Halothane, Enflurane, Isoflurane,
Sevoflurane, Desflurane

Halothane, Enflurane, Isoflurane,
Sevoflurane, Desflurane


Gas supply


O2, or O2+N2O, or O2+N2O+Air


O2, or O2+N2O


O 2, or O 2+N 2O
Input pressure
280~650 kpa


280~650 kpa
(350~400kpa is recommended)

280~650 kpa
(350~400kpa is recommended)

Standard vent. mode

VCV, PCV,PLV

VCV, PCV,PLV

VCV, PLV


Optional vent. mode

PCV, PSV, SIMV+VCV+PS, SIMV+PCV+PS

PCV (for 3000PS)
optional mechanical PEEP




Electronic PEEP




YES




 YES/NO




 NO



Display screen



Built-in 8.4" color



Built-in 5.7" monochrome



Built-in 3.0" LCD/LED

Value display (Set and measured)



Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit
Airway pressure (Ppeak, Pmean, Pmax, 

Pplateau, PEEP)
FiO2%, Compliance (ml/cmH2O) Pressure support level, Inspiratory Window, P-trigger, Inspiratory End
EtCO2 and InCO2 (optional)
CSI, BS%, SQI%, EMG%


Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit
 
Airway pressure (Ppeak, Pmean, Pmax, Pplateau, PEEP)
FiO2%, Compliance (ml/cmH2O)

Tidal volume, minute volume, respiratory rate, I:E ratio, pressure limit
 
Airway pressure (Ppeak, Pmean, Pmax, Pplateau, PEEP)
FiO2%


Graphic display

P-T, F-T, V-T waveforms
P-V, P-F, F-V loops (for compliance, resistance, leakage analysis)
 

EtCO2 waveforms (when optional EtCO2 module is present)
CSI, BS%, SQI, EMG waveforms (when optional CSM is present)


P-T


P-T
Optional expansion


Anesthetic gas scavenging system
EtCO2 module (mainstream/sidestream)
Anesthesia information management system
External patient monitor
Other equipment


Anesthetic gas scavenging system
Anesthesia information management system
External patient monitor
Other equipment


Anesthetic gas scavenging system
Anesthesia information management system
External patient monitor
Other equipment





没有评论: