Applications
Our Deluxe-140 multi-parameter monitor is suitable for monitoring parameters of
ECG, RESP, NIBP, SpO2 and TEMP. Other optional monitoring
applications are also available, such as mainstream, sidestream EtCO2
and 1 or 2-Channel IBP.
Features
1. Deluxe-140 multi-parameter monitor comes with a 14.1"color TFT display.
Up to 9 curves can be simultaneously displayed.
2. It has accessories for adult, neonatal and pediatric patients.
3. The multi-parameter monitor provides visual and audible alarms with individual alarm setting.
4. Maximum 480 hours trend graphs enable nearly all parameters and trends to be listed for further analysis.
5. The patient monitor allows storage of up to 1000 groups of NIBP data.
6. It can be wall mounted or mounted with rolling stand.
7. Network capability with PC-1000 PRO central monitoring system is available.
2. It has accessories for adult, neonatal and pediatric patients.
3. The multi-parameter monitor provides visual and audible alarms with individual alarm setting.
4. Maximum 480 hours trend graphs enable nearly all parameters and trends to be listed for further analysis.
5. The patient monitor allows storage of up to 1000 groups of NIBP data.
6. It can be wall mounted or mounted with rolling stand.
7. Network capability with PC-1000 PRO central monitoring system is available.
Specifications of Deluxe-140 Multi-Parameter Monitor
ECG
|
Heart
rate display range
|
15bpm
~ 350bpm
|
|
Heart
rate display accuracy
|
± 1% or ± 2bpm,
whichever is greater
|
||
Sweeping
speed
|
12.5mm/s,
25mm/s, 50mm/s
|
||
Sensitivity
selection
|
×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
|
||
CMRR
|
≥ 89dB
|
||
RESP
|
Measuring
range
|
0rpm~120rpm
|
|
Accuracy
|
±5% or ±2 rpm
|
||
Alarm
limits setting range
|
0rpm~120rpm
|
||
TEMP
|
Measuring
range
|
25.0℃ ~45.0℃
|
|
Measuring
accuracy
|
±0.2℃
|
||
Responding
time
|
≤150s
|
||
NIBP
|
Measuring
method
|
Oscillometric
Technique
|
|
Measuring
range
|
0mmHg~300mmHg
|
||
Accuracy
|
Maximal
mean difference
|
±5 mmHg
|
|
Maximal
standard deviation
|
8 mmHg
|
||
Measurement
range
|
Adult
|
SYS 40
~ 255 mmHg
|
|
MAP 20
~ 215 mmHg
|
|||
DIA 10
~ 195 mmHg
|
|||
Pediatric
patient
|
SYS 40
~ 200 mmHg
|
||
MAP 20
~ 165 mmHg
|
|||
DIA 10
~ 150 mmHg
|
|||
Neonate
|
SYS 40
~ 135 mmHg
|
||
MAP 20
~ 110 mmHg
|
|||
DIA 10
~ 95 mmHg
|
|||
SpO2
|
Measuring
range
|
35%~100%
|
|
Low perfusion
capability
|
0.4%~5%
|
||
Accuracy
|
Not
greater than 3% for SpO2range from 70% to 100%
|
||
PR
|
Measuring
range
|
30bpm~240bpm
|
|
Measuring
accuracy
|
±2bpm or ±2%,
whichever is greater
|
Heal
Force is a professional multi-parameter monitor manufacturer based in China. We also
offer vital signs monitor, surgical operating table, fingertip pulse
oximeter, and laboratory centrifuge, among others.