Genius-15 Multi-Parameter
Monitor
Applications
Genius-15 multi-parameter monitor is especially designed for anaesthesia use.
It can monitor standard parameters of ECG, SpO2, RESP, NIBP, TEMP
and PR. With.a CSM module, it can also monitor parameters of CSI, EEG, EMG and
BS% with alarm.
Features
1. Genius-15 multi-parameter monitor comes with a 15" high resolution
color LCD screen.
2. It uses a built-in printer which allows printing of values and curves if needed.
3. It has a portable handset with wireless connection to main unit for data processing.
4. The multi-parameter monitor adopts digital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
5. It offers optimized NIBP measurement modes for adult, neonatal and pediatric patients.
6. It allows automatic analysis of 20 arrhythmia waveforms.
7. The multi-parameter monitor can store up to 400 groups of data as well as 24 hour ECG waveforms.
8. It provides protection against interference from defibrillator and electrosurgical generator.
9. Automatic and manual analysis is available for S-T segment.
2. It uses a built-in printer which allows printing of values and curves if needed.
3. It has a portable handset with wireless connection to main unit for data processing.
4. The multi-parameter monitor adopts digital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
5. It offers optimized NIBP measurement modes for adult, neonatal and pediatric patients.
6. It allows automatic analysis of 20 arrhythmia waveforms.
7. The multi-parameter monitor can store up to 400 groups of data as well as 24 hour ECG waveforms.
8. It provides protection against interference from defibrillator and electrosurgical generator.
9. Automatic and manual analysis is available for S-T segment.
Specifications
of Genius-15 Multi-Parameter Monitor
CSM
|
EEG sensitivity
|
±400μV
|
|
Noise level
|
<2μVp-p, <0.4μV RMS, 1~250Hz
|
||
CMR
|
>140dB
|
||
Input impedance
|
>50Mohm
|
||
Sample rate
|
2000 samples/sec. (14 bits equivalent)
|
||
CSI and update
|
0-100. Filter 6-42Hz, 1sec. update
|
||
EMG
|
0-100 logarithmic. Filter 75-85Hz, 1 sec. update
|
||
BS%
|
0-100%. Filter 2-42Hz, 1 sec. update
|
||
Wireless range
|
Up to 10 meters
|
||
ECG
|
Heart rate display range
|
15bpm ~ 350bpm
|
|
Heart rate display accuracy
|
± 1% or ± 2bpm, whichever is greater
|
||
Sweeping speed
|
12.5mm/s, 25mm/s, 50mm/s
|
||
Sensitivity selection
|
×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
|
||
CMRR
|
≥ 89dB
|
||
RESP
|
Measuring range
|
0rpm~120rpm
|
|
Accuracy
|
±5% or ±2 rpm
|
||
Alarm limits setting range
|
0rpm~120rpm
|
||
TEMP
|
Measuring range
|
25.0℃ ~45.0℃
|
|
Measuring accuracy
|
±0.2℃
|
||
Responding time
|
≤150s
|
||
NIBP
|
Measuring method
|
Oscillometric Technique
|
|
Measuring range
|
0mmHg~300mmHg
|
||
Accuracy
|
Maximal mean difference
|
±5 mmHg
|
|
Maximal standard deviation
|
8 mmHg
|
||
Measurement range
|
Adult
|
SYS 40 ~ 255 mmHg
|
|
MAP 20 ~ 215 mmHg
|
|||
DIA 10 ~ 195 mmHg
|
|||
Pediatric patient
|
SYS 40 ~ 200 mmHg
|
||
MAP 20 ~ 165 mmHg
|
|||
DIA 10 ~ 150 mmHg
|
|||
Neonate
|
SYS 40 ~ 135 mmHg
|
||
MAP 20 ~ 110 mmHg
|
|||
DIA 10 ~ 95 mmHg
|
|||
SpO2
|
Measuring range
|
35%~100%
|
|
Low perfusion capability
|
0.4%~5%
|
||
Accuracy
|
Not greater than 3% for SpO2range from 70% to
100%
|
||
PR
|
Measuring range
|
30bpm~240bpm
|
|
Measuring accuracy
|
±2bpm or ±2%, whichever is greater
|
||
General
|
Power supply
|
100~240VAC, 50/60Hz
|
|
Rechargeable Li-ion battery
|
12V 2.3Ah
|
||
Display mode
|
15 inches TFT color LCD
|
||
Alarming mode
|
Audible and visible alarm
|
As a China-based
multi-parameter monitor manufacturer, Heal Force supplies a broad range of
products, including surgical light, anesthetic machine, fingertip pulse
oximeter, laboratory centrifuge, and others.
没有评论:
发表评论