Applications
Our UP-8000 multi-parameter monitor is used for monitoring standard parameters
of ECG, SpO2, RESP, NIBP, TEMP and PR. With a CSM module, it can
also monitor parameters of CSI, EEG, EMG and BS% with alarms. The patient
monitor is especially designed for anaesthesia use.
Features
1. The UP-8000 multi-parameter monitor uses a 12.1" high resolution color
LCD screen.
2. It has a portable handset with wireless connection to main unit for data processing.
3. The multi-parameter monitor offers optimized NIBP measurement modes for adult, neonatal and pediatric patients.
4. It achieves automatic analysis of 20 arrhythmia waveforms.
5. Both automatic and manual analysis is available for S-T segment.
6. The patient monitor adopts digital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
7. It can store up to 400 groups of data as well as 24 hour ECG waveforms.
8. The multi-parameter monitor offers protection against interference from defibrillator and electrosurgical generator.
9. It has a built-in thermal printer.
2. It has a portable handset with wireless connection to main unit for data processing.
3. The multi-parameter monitor offers optimized NIBP measurement modes for adult, neonatal and pediatric patients.
4. It achieves automatic analysis of 20 arrhythmia waveforms.
5. Both automatic and manual analysis is available for S-T segment.
6. The patient monitor adopts digital SpO2 technology that helps ensure anti-motion and anti-low perfusion.
7. It can store up to 400 groups of data as well as 24 hour ECG waveforms.
8. The multi-parameter monitor offers protection against interference from defibrillator and electrosurgical generator.
9. It has a built-in thermal printer.
Specifications of UP-8000 Multi-Parameter Monitor
CSM
|
EEG
sensitivity
|
±400μV
|
|
Noise
level
|
<2μVp-p, <0.4μV RMS, 1~250Hz
|
||
CMR
|
>140dB
|
||
Input
impedance
|
>50Mohm
|
||
Sample
rate
|
2000
samples/sec. (14 bits equivalent)
|
||
CSI
and update
|
0-100.
Filter 6-42Hz, 1sec. update
|
||
EMG
|
0-100
logarithmic. Filter 75-85Hz, 1 sec. update
|
||
BS%
|
0-100%.
Filter 2-42Hz, 1 sec. update
|
||
Wireless
range
|
Up to
10 meters
|
||
ECG
|
Heart
rate display range
|
15bpm
~ 350bpm
|
|
Heart
rate display accuracy
|
± 1% or ± 2bpm,
whichever is greater
|
||
Sweeping
speed
|
12.5mm/s,
25mm/s, 50mm/s
|
||
Sensitivity
selection
|
×1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV
|
||
CMRR
|
≥ 89dB
|
||
RESP
|
Measuring
range
|
0rpm~120rpm
|
|
Accuracy
|
±5% or ±2 rpm
|
||
Alarm
limits setting range
|
0rpm~120rpm
|
||
TEMP
|
Measuring
range
|
25.0 ℃ ~45.0℃
|
|
Measuring
accuracy
|
±0.2 ℃
|
||
Responding
time
|
≤150s
|
||
NIBP
|
Measuring
method
|
Oscillometric
Technique
|
|
Measuring
range
|
0mmHg~300mmHg
|
||
Accuracy
|
Maximal
mean difference
|
±5 mmHg
|
|
Maximal
standard deviation
|
8 mmHg
|
||
Measurement
range
|
Adult
|
SYS 40
~ 255 mmHg
|
|
MAP 20
~ 215 mmHg
|
|||
DIA 10
~ 195 mmHg
|
|||
Pediatric
patient
|
SYS 40
~ 200 mmHg
|
||
MAP 20
~ 165 mmHg
|
|||
DIA 10
~ 150 mmHg
|
|||
Neonate
|
SYS 40
~ 135 mmHg
|
||
MAP 20
~ 110 mmHg
|
|||
DIA 10
~ 95 mmHg
|
|||
SpO2
|
Measuring
range
|
35%~100%
|
|
Low
perfusion capability
|
0.4%~5%
|
||
Accuracy
|
Not
greater than 3% for SpO2range from 70% to 100%
|
||
PR
|
Measuring
range
|
30bpm~240bpm
|
|
Measuring
accuracy
|
±2bpm or ±2%,
whichever is greater
|
||
General
|
Power
supply
|
100~240VAC,
50/60Hz
|
|
Rechargeable
Li-ion battery
|
12V
2.3Ah
|
||
Display
mode
|
12
inches TFT color LCD
|
||
Alarming
mode
|
Audible
and visible alarm
|